Features:
|
· Replaces the conventional thermostat with a digital system.
· Digital water temperature reading/setting. Four settings per day.
· Control your geyser from the controller
· Convenient to operate.
· Microprocessor Intelligent Control.
· Quick and steady water temperature control.
· Power off memory timer.
· Earth leakage protection.
· High temperature cut out at 85 degrees centigrade. |
· Element failure detection.
· Leading hot water pipe detection.
· Scale build-up detection.
· Probe failure detection.
· Load shifting capability to off peak periods.
· Real-time clock.
· Four daily programmable time settings, Monday to Friday, Saturday and Sundays.
· Battery backup on power failure. |
Technical Specifications:
REPLACE CONVENTIONAL THERMOSTAT TESTED BY SABS COMMERCIAL (PTY)LTD IN TERMS OF STANDARD IEC 60950
|
AVERAGE OPERATING VOLTAGE |
|
AC 220V / 50HZ |
|
|
|
|
|
OPERATING VOLTAGE RANGE |
|
AC 160V TO 250V |
|
|
|
|
|
MAXIMUM CURRENT |
|
30 AMPERE |
|
|
|
|
|
EARTH LEAKAGE PROTECTION |
|
25mA, Action time = 0.1s |
|
|
|
|
|
TEMPERATURE DISPLAY |
|
0 TO 99° C |
|
|
|
|
|
TEMPERATURE SETTING RANGE |
|
30 TO 75° C |
|
|
|
|
|
MAXIMUM TEMPERATURE |
|
85° C |
|
|
|
|
|
BI-POLAR RELAY |
|
ISOLATE ELEMENT IN OFF POSITION |
For safety reasons and to avoid any further damage the unit will display an error code and shut the system down under the following conditions
1. Earth Leakage
2. Element Failure
3. Overheating > 85°C
4. Sense Heat Failure e.g. scale build-up, leaking pipes
5. Probe Failure
Supports telephone remote control on/off, ability to interface with alarm systems.
|